Pelvis #2

  1. Nonunion of femoral neck fracture, leading to fracture of dynamic hip screw.

Findings

  1. Fracture of the large lag screw of the dynamic hip screw (black arrow).
  2. Ununited fracture line in left femoral neck (white arrow).



AP view of the pelvis and detail view of left hip

Brief Discussion


Orthopaedic hardware does not fracture without reason. The usual reason is excessive motion about the fracture site, which may be due to an ununited fracture.